Index
|
Flow
|
L/Min
|
30
|
50
|
100
|
150
|
200
|
250
|
300
|
Working vacuity
|
MPa
|
-0.08 — -0.099
|
Working pressure
|
MPa
|
≤0.4
|
Constant temperature control range
|
℃
|
20 — 80
|
Power
|
V
|
380V 50HZ(or according to customer needs)
|
Noise
|
dB(A)
|
≤65~85(according to configuration)
|
Electric heating power
|
KW
|
30
|
30
|
72
|
96
|
144
|
168
|
192
|
Total power
|
KW
|
35
|
35
|
80
|
105
|
155
|
182
|
206
|
Inlet/outlet diameter
|
mm
|
25
|
32
|
42
|
50
|
50
|
60
|
60
|
Weight
|
Kg
|
600
|
750
|
870
|
950
|
1250
|
1850
|
2100
|
Size
|
length
|
mm
|
1500
|
1500
|
1950
|
2100
|
2200
|
2250
|
2400
|
width
|
mm
|
1250
|
1350
|
1300
|
1350
|
1350
|
1400
|
1450
|
height
|
mm
|
1700
|
1750
|
2100
|
2200
|
2200
|
2200
|
2200
|
treatment index
|
Breakdown voltage
|
KV
|
≧70(GB/T507)
|
Water content
|
PPm
|
≤5(GB/T7600)
|
Air content
|
%
|
≤0.1(GB/T423)
|
Filtering accuracy
|
μm
|
≤3
|
Application
It is generally used in outdoor mobile operation, such as large-scale installation and maintenance equipment in power industry (such as vacuum oil filter, vacuum pumping unit, vacuum drying equipment, etc.), and it is also used in the application of oil treatment equipment frequently moved in the factory area of large enterprises.